Model Number | DN47 |
Type | Mini |
Poles Number | 1-4P |
Mechanical life | no less than 20000 |
Rated voltage | 240V/415V |
protective characteristics | 400C |
Breaking capacity | 3KA/4.5KA |
Port | NINGBO |
Lead Time | 10-20 days |
1) DN47-63 series electric circuit breaker is used in lighting or motor distribution system for protecting overload and short circuit in the system.
2) The product is neoteric in structure light in weight, reliable and excellent in performance .
3) Its frame and parts adopt plastics of high fire resistant and shockproof.
4) The product overload and short circuit protection, as well as for infrequent switching on&of electric equipment and lighting circuit in normal case.
5) The products comply with IEC60898
1) Setting temperature of protective characteristics at 400C
2) Rated Voltage:240V/415V DZ47-63 series electric circuit breaker
3) Rated Current:1,3,6,16,20,25,32,40,50,63A
4) Electrical life: no less than 6000 operations
5) Mechanical life:(O-C)no less than 20000 DZ47-63
Manufacturing Standards |
IEC 60898 IEC60947 |
||
Tropicalization |
Relative Humidity |
°C |
93% RH at 25°C |
|
Room Temperature |
°C |
10°Ca 60°C |
Electrical Properties |
Rated at 40°C |
A |
6/10/16/20/25/32/40/50/63 |
|
Rated operating voltage at 40°C |
Vac |
240/415 |
|
Nominal Frequency |
Hz |
50/60 |
|
Interrupting Capacity at 230 V |
kA |
6 |
|
Operating temperature |
°C |
40 |
|
Degree of Protection |
|
IP20 |
|
Number of poles |
|
1/2/3/4 |
|
Conductor cross section (minimum allowable) |
mm2 |
25 |
|
Minimum number of power moves |
|
4000 |
|
Minimum number of mechanical operations |
|
10000 |
|
Operation curve |
|
B/C/D |
|
Current Trip Curve |
A |
5 a 10 In |
|
Characteristic Intervention |
|
attach |
Type Of Assembly |
FOR RIEL DIN 35 mm |
||
Features |
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D ) | ||
|
BIMETAL: ensures the breaker trip when overloaded. | ||
|
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. | ||
Present Certificates |
CE CB | ||
|
ISO 9001-2000 awarded by the competent certification body, Nonarc is qualified in the manufacturing of the object | ||
|
IEC 60898 standards in the manufacture of the goods | ||
|
Curve compliance issued Shot by an accredited laboratory for effect | ||
|
Life, given by Nonarc to ensure that the life of the goods offered by at least 15 years. | ||
Testing For Acceptance |
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. |
DZ47-63(C) | ||||
Rated current(A) |
Pole number |
Voltage(V) |
Breaking capacity |
|
1~40 |
1P |
230 |
4500 |
|
1~40 |
2,3,4P |
400 |
4500 |
|
50~60 |
1P |
230 |
3000 |
|
50~60 |
2,3,4P |
400 |
3000 |
DZ47-63(D) | ||||
Rated current(A) | Pole number | Voltage(V) | Breaking capacity | |
1~60 | 1P | 230 | 4000 | |
1~60 | 2,3,4P | 400 | 4000 |
* FAST SHIPPING from our Wenzhou China Factory!
* Item shipped in 5-15 working days after payment is received depends on the quantity of the order.
* Item shipped by UPS,FedEX,DHL and others, depending on size and weight of total order.
* Item only shipped to address listed on the invoice; Not responsible for shipping to wrong address.
* Tracking number will be sent to you as soon as we ship the goods.