Factory direct sale kema vde mcb 10KA rogy circuit breaker


  • Brand Name: NBSe
  • Model Number: BN60
  • Certificate: CE, ISO9001
  • Product name: MCB Circuit Breaker
  • Breaking capacity: 10KA
  • Rated voltage: 12V~1000V DC
  • Rated current: 1A-63A
  • Material : Plastic
  • Type: BN60
  • Package Type: 240PCS/CTN
  • Supply Ability: 600000 Piece/Pieces per Month
  • Factory direct sale: kema vde mcb 10ka rogy circuit breaker
  • Product Detail

    Product Tags

    ava (5)
    ava (4)
    ava (3)

    Product picture

    BN60 Circuit Breaker has 1 pole, 2 pole, 3 stage and 4 pole intended for use in circuit breakers,Used in shopping malls, base stations,home power into the line board control terminal.

    avca

    Specifications and Configuration

    Rated Current In: 6A,10A,16A,20A,25A,32A,40A,50A,63A

    Breaking Capacity: 10KA

    Trip curve:B、C、D

    Product Implementation Standard:IEC60898.1,GB/T 10963.1

    Installation Condition:

    a)Ambient air temperature

    Considering that high ambient temperature accelerates the aging of plastic parts, the

    upper limit shall not exceed +40℃

    Considering the excessively low ambient temperature changes the fit of structural

    parts, the lower limit value is generally not less than -5℃. Considering the service

    life of the circuit breaker, the average value of 24 hours is not more than +35℃.

    Note: ① The working conditions with the lower limit of -10℃ or -25℃ shall be

    declared to the company when ordering.

    ② If the upper limit exceeds +40℃ or the lower limit is lower than -25℃, the user

    shall negotiate with the company.

    b)Installation location

    The altitude is not more than 2000m;

    Protection circuit requirements;

    Short-circuit current Ik calculated at installation point is not more than 6000A;

     c)Atmospheric conditions:

    The atmospheric relative humidity does not exceed 50% when the ambient air temperature is +40℃, and can have a higher relative humidity at lower temperatures. The monthly average maximum relative humidity in the wettest month is 90%, while the average minimum temperature in the month is +25℃ and the condensation on the product surface due to temperature changes.

    d) Pollution level: Pollution level is III.

    e) Installation category:

    The installation category of Circuit Breaker protection circuit is Ⅲ

    f)The traverse section is configured according to the maximum agreed heating current Ith of the circuit breaker.

    Interpretation of technical Parameters :

    Technical parameters of circuit breaker Chart 1,Chart 2

    Chart 1 Overload protection feature parameter

    1.13In

    1.45In

    No-trip within 1 hour

    No-trip within 1 hour

    Chart 2 Instantaneous protection trip interval

    Trip curve type

    B

    C

    D

    Protected non-trip interval

    3In

    5In

    10In

    Protection trip interval

    5In

    10In

    15In